Tensile Load Requirements for Bolts Tested Full-Size

Bolt Size

Threads per

inch and Series

Designation

Stress Area,in.²

Tensile Load,

min,lbf 

Proof Load,

Length Measurement

Method

Alternative Proof 

Load,Yield

Strength Method

Column 1Column 2Column 3Column 4Column 5
1/2-13 UNC0.142170501205013050
5/8-11 UNC0.226271001920020800
3/4-10 UNC0.334401002840030700
7/8-9 UNC0.462554503925042500
1/8 UNC0.606727005150055750
1-1/8-7 UNC0.763801005645061800
1-1/4-7 UNC0.9691017007170078500
1-3/8-6 UNC1.1551213008545093550
1-1/2-6 UNC1.405147500104000113800